![]() ![]() If you want me to look it up and see which control board that Lennox recommends for your furnace then please send me your furnace’s model number to our email address and I will be glad to look it up and give you the recommended Lennox control board part number. If you are getting 24 volts to the PV and the gas valve will not light the pilot then I would think that you have a bad gas valve. ![]() I would like to suggest that you test with a voltmeter to see if you are getting 24 volts to the PV if not then you might have a bad control board, wrong control board, or an open safety control (pressure switch, limit, or rollout) that is not allowing the pilot to light. If you have a gas valve that has a PV (pilot valve) and an MV (main valve) then I would think that either you are not getting the 24 volts to the PV since the pilot is not lighting to continue the furnace ignition sequence. Hi Steve! This sounds like your furnace is sparking (clicking) but there is not any ignition to the pilot.